1.Engraving machine in
continuous running for ten hours every day, must ensure the cooling water
cleaning and water pump normal work, must not let the water spindle motor to be
short of water. Replace cooling water regularly to avoid too high water
temperature. In winter, if the working environment of the engraving machine is
too low, the water inside the tank can be changed into antifreeze.
2.Every time you use
the engraving machine, you should pay attention to cleaning. You must clean the
dust on the transmission system, and lubricate the transmission system
regularly. (Note: the polished rod of X, Y, and Z three axis should be
maintained by machine oil;
Add some high speed butter to the screw rod;The
work temperature is low in winter, the polished rod and the screw rod can be cleaned with kerosene firstly, then add machine oil.Otherwise,
There will be too much resistance in the transmission parts of the engraving
machine, causing the machine to be misaligned)
3.Be sure to cut off
the power when maintaining and testing the machine.Wait until the monitor does
not show and the main circuit power indicator goes out.
4.After three months
use, the engraving machine should be checked for fasteners. The connecting screws
on both sides of the gantry, the fastening screws of the motor on both sides
and the fastening screws of the feed screw nut all need
to be tightened again.